Yes, just need delivery the cable to JDD factory.
I.D.= W. (natural width) x 2/π – wall thikness
If you would like to cut into 10mm long with quantity 500,000pcs, set the
tolerance within 10.1~10.5mm, so the actual computation: 500,000pcs×10.1mm=5050m
or 500,000pcs×10.5mm=5250m at least
The cutting tolerance caused
1. Choose expandable sleeving with a large expansion rate, which is larger
than the cable connector and plug after expansion.
2. Choose Velcro wrap, zipper wrap, self-closing wraps or another cable
wrap.
Choose the cable wrap, such as the self-closing wrap, with the split design
and installation tools.
1. Use a high temperature cutting tools, such as Jdd 's hot knife, or a hot
wire device (customer made).
2. Burn the edge with a lighter after cutting it.
3. Customers can also buy a cold cut sleeve directly.
4. Use a heat-shrinkable tube to fix the edge after cutting.